Electrolux EHT6432K Manuel d'utilisateur Page 23

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 36
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 22
electrolux 23
Fault Finding
Preliminary Electrical Systems Check
START
Isolate appliance
and carry out:
A: Earth Continuity
check.
Has inlet fuse blown?
Carry out:
C: Polarity check.
Electricity supply
should now be
satisfactory.
Carry out:
D: Resistance to
Earth check.
Inlet wiring
faulty.
Rectify any
fault.
Isolate appliance and
carry out:
B: Insulation check.
Rectify any fault
including replacing
fuses as necessary.
NO
YES
SOCKET
(face view)
PLUG (with cover removed)
Earth Wire
Green/Yellow
Neutral Wire
Blue
( )
FUSE
( )
E
N
L
Brown
Blue
Green
Yellow
Green
Yellow
Brown
Blue
NO YES
Vue de la page 22
1 2 ... 18 19 20 21 22 23 24 25 26 27 28 ... 35 36

Commentaires sur ces manuels

Pas de commentaire