Electrical connections
The appliance is designed to be connected to 230 V monophase
electricity supply.
The connection must be carried out in compliance with the laws and
regulations in force.
Before the appliance is connected:
1) check that the main fuse and the domestic installation can support the
load (see the rating label);
2) check that the power supply is properly earthed in compliance with the
current rules;
3) check the socket or the double pole switch used for the electrical
connection can be easily reached with the appliance built in the forniture
unit.
The appliance is supplied with a connection cable. This has to be provided
with a proper plug, able to support the load marked on the identification
plate. The plug has to be fitted in a proper socket.
If connecting the appliance directly to the electric system, it is necessary
that you install a double pole switch between the appliance and the
electricity supply, with a minimum gap of 3 mm. between the switch
contacts and of a type suitable for the required load in compliance with the
current rules.
The connection cable has to be placed in order that, in each part, it cannot
reach a temperature higher than 90°C.
The brown coloured phase cable (fitted in the terminal block contact
marked with "L") must always be connected to the network phase
.
Replacement of the voltage cable
The replacement of electric cable
must be carried out exclusively by
the service force centre or by
personnel with similar
competencies, according to the
current regulations in force.
The connection of the voltage cable to the
appliance's terminal block is of type "Y". This
means that its replacement requires the
specific equipment of a technician. In this case,
only cable type H05V2V2-F T90 must be
used. The cable section must be suitable to
the voltage and the working temperature. The
yellow/green earth wire must be
approximately 2 cm. longer than the phase wires.
Neutral
Earth (yellow/green)