Vue de la page 22
Minimum distances
Dimension mm
A 400
B 650
C 150
D 20
14.2 Technical data
Voltage 220 V
Frequency 50 Hz
Appliance class 1
Dimension mm
Height 855
Width 600
Depth 600
14.3 Other technical data
Appliance category: II2H3B/P
Gas original: G20 (2H) 20 mbar
Gas replacement: G30/G31 (3B/P) 30/30 mbar
14.4 Bypass diameters
BURNER
Ø BYPASS
1)
1/100 mm
Auxiliary 29 / 30
Semi-rapid 32
Rapid 42
Oven 44
1)
Type of bypass depends on model.
14.5 Gas burners for NATURAL GAS G20 20 mbar
BURNER NORMAL POW‐
ER kW
REDUCED POWER kW INJECTOR MARK
1/100 mm
Rapid 3.0
0.72 / 0.75
1)
119
Semi-rapid
2.0 / 1.9
1)
0.43 / 0.45
1)
96
Auxiliary 1.0 0.35 70
Oven 2.7 0.90 120
Grill 1.9 - 108
1)
Type of bypass depends on model.