10.4 Gas burners for NATURAL GAS G20 20 mbar
BURNER NORMAL POWER
kW
MINIMUM POWER
kW
INJECTOR MARK
1/100 mm
Triple Crown 4,0 1,4 146
Semi-rapid
- Bridge burner
2,0 0,75 96
Auxiliary 1,0 0,45 70
10.5 Gas burners for LPG G30/G31 28-30/37 mbar
BURNER NORMAL
POWER
kW
MINIMUM
POWER
kW
INJECTOR
MARK 1/100
mm
NOMINAL GAS FLOW g/h
G30 28-30
mbar
G31 37 mbar
Triple
Crown
4,0 1,4 98 291 286
Semi-rapid
- Bridge
burner
2,0 0,75 71 145 143
Auxiliary 1,0 0,45 50 73 71
11. ENERGY EFFICIENCY
11.1 Product information according to EU 66/2014
Model identification EGH6349GOX
Type of hob Built-in hob
Number of gas burners 4
Energy efficiency per gas burner
(EE gas burner)
Left rear - Auxiliary not applicable
Right rear - Semi-rapid-Bridge
burner
53.7%
Left front - Triple Crown 52.0%
Right front - Semi-rapid-Bridge
burner
53.7%
Energy efficiency for the gas hob
(EE gas hob)
53.1%
EN 30-2-1: Domestic cooking appliances burning gas - Part 2-1 : Rational use of
energy - General
11.2 Energy saving
• Before use, make sure that the burners and pan supports are assembled correctly.
• Use cookware with diameters applicable to the size of burners.
www.electrolux.com18