To replace the connection
cable use only H03V2V2-F
T90 or equivalent type.
Make sure that the cable
section is applicable to the
voltage load and the working
temperature. The yellow/
green earth wire (B) must be
approximately 2 cm longer
than the live and neutral wire
(A).
A B
1. Connect the green and yellow (earth)
wire to the terminal which is marked
with the letter 'E', or the earth symbol
, or coloured green and yellow.
2. Connect the blue (neutral) wire to the
terminal which is marked with the
letter 'N' or coloured blue.
3. Connect the brown (live) wire to the
terminal which is marked with the
letter 'L'. It must always be connected
to the network phase. There must be
no cut or stray strands of wire
present. The cord clamp must be
correctly attached to the outer
sheath.
8.8 Assembly
1.
2.
3.
min.
55 mm
min.
650 mm
560 mm
480 mm
min.
150 mm
30 mm
4.
50 mm
400 mm