Electrolux EHT 60418 Instructions d'exploitation Page 19

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 48
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 18
electrolux 19
Building In
A = Auxiliary burner
SR = Semi-rapid burner
R = Rapid burner
Dimensions are given in millimeters
The hob can be inserted in a built-in kitchen unit
whose depth is between 550 mm and 600 mm.
The hobs dimensions are shown in Fig. 5.
The edge of the cut out must have a minimum
distance from the rear wall of 55 mm.
If there are side walls, or sides of the furniture unit
near the hob, the cut out edges must have a
minimum distance of 150 mm.
Hanging forniture units or hoods must be placed
at 650 mm minimum from the hob.
580
510
R
SR
SR
A
Fig. 5
Fig. 6
Vue de la page 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 47 48

Commentaires sur ces manuels