BURNER Ø BYPASS 1/100 mm
Rapid 42
Oven 50
Grill 50
13.5 Gas burners for LPG G30 28-30 mbar
BURNER NORMAL
POWER kW
GAS RATE g/h REDUCED
POWER kW
INJECTOR
MARK 1/100 mm
Rapid 3.0 218.1 0.72 88
Semi-rapid 2.0 145.4 0.43 71
Auxiliary 1.0 72.7 0.35 50
Oven 2.5 181.8 1.0 75
Grill 2.4 174.5 1.5 75
13.6 Gas connection
WARNING!
Before you connect the gas,
disconnect the appliance
from the electricity supply or
switch off the fuse in the
fuse box. Close the primary
valve of the gas supply.
The gas pipe in the appliance has two
endings. You can connect the gas supply
to either one of them. The pipe that is not
used must be clogged with the pipe
closer, which added to the appliance.
Use a fixed connections or use a flexible
stainless steel pipes in compliance with
the regulation in force. If you use flexible
metallic pipes, make sure they do not
come in touch with mobile parts and they
are not squeezed.
WARNING!
When installation is
complete, make sure that
the seal of each pipe fitting
does not leak. To check the
seal use a soap solution, not
a flame.
13.7 Flexible nonmetal pipes
connection
If you have an easy access to the
connection, you can use a flexible pipe.
The flexible pipe must be tightly attached
by clamps.
In installation always use the pipe holder
and the gasket. The flexible pipe can be
applied when:
www.electrolux.com22