Electrolux EKG913A2OX Manuel d'utilisateur Page 24

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 32
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 23
Natural Gas: G20 (2H) 20 mbar
14.4 Bypass diameters
BURNER Ø BYPASS 1/100 mm
Auxiliary 29 / 30
Semi-rapid 32
Rapid 42
Dual 67
Oven 54
Grill 59
14.5 Gas burners for NATURAL GAS G20 20 mbar
BURNER NORMAL POW‐
ER kW
REDUCED POWER kW INJECTOR MARK
1/100 mm
Dual 4.5 1.8 150
Rapid 3.0 0.72 119
Semi-rapid 2.0 0.43 96
Auxiliary 1.0 0.35 70
Oven 3.9 1.5 139
Grill 3.0 1.6 126
14.6 Gas burners for LPG G30 28-30 mbar
BURNER NORMAL POW‐
ER kW
REDUCED POWER kW INJECTOR MARK
1/100 mm
Dual 4.5 1.8 104
Rapid 3.0 0.72 88
Semi-rapid 2.0 0.43 71
Auxiliary 1.0 0.35 50
Oven 3.9 1.5 95
Grill 3.0 1.6 88
14.7 Gas Connection
The gas pipe in the appliance has two
endings. You can connect the gas supply
to either one of them. The pipe that is not
used must be clogged with the pipe
closer, which added to the appliance.
Use a fixed connections or use a flexible
stainless steel pipes in compliance with
the regulation in force. If you use flexible
www.electrolux.com24
Vue de la page 23
1 2 ... 19 20 21 22 23 24 25 26 27 28 29 30 31 32