Electrolux EDC67550W Manuel d'utilisateur Page 15

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 20
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 14
Programme
Energy consumption in kWh / average
drying time in min.
COTTON CUPBOARD (COTTON CUP-
BOARD)
2)
3)
3.92 / 125 (7 kg load pre-drained at 1000
rpm)
3,6 / 119 (7 kg load pre-drained at 1400 rpm)
COTTON IRON (COTTON IRON)
2)
3.34 / 107 (7 kg load pre-drained at 1000
rpm)
SYNTHETICS CUPBOARD (SYNTHETICS
CUPBOARD)
2)
1.33 / 48 (3 kg load pre-drained at 1200 rpm)
1) Different loading volume data may be needed in some countries as a result of different measuring
methods.
2) in accordance with EN 61121
Machine settings
Setting Implementation
BUZZER (BUZZER ) perma-
nent off
1. Turn the programme selector to any programme.
2. Press simultaneously the BUZZER and DRYNESS buttons and
hold down for approx. 5 seconds.
3.
The buzzer is by default always off. You can use BUZZER button
to activate or deactivate sound but machine does not memorize
your selection.
Water hardness
Water contains, a variable
quantity of limestone and min-
eral salts of which quantities
vary according to geographical
locations thus varying its con-
ductivity values.
Relevant variations of the con-
ductivity of the water compared
to those prefixed by the factory
could slightly influence the re-
sidual humidity of the laundry at
the end of the cycle. Your dryer
allows you to regulate the sen-
sitivity of the drying sensor
based on conductivity values of
the water.
1. Turn the programme selector to any programme.
2. Press simultaneously the DRYNESS and START/PAUSE but-
tons and hold down for approx. 5 seconds. The current setting
is on the display:
low conductivity <300 micro S/cm
medium conductivity 300-600 micro S/cm
high conductivity >600 micro S/cm
3. Press the START PAUSE START PAUZE button sequentially
until you set desired level.
4. To memorize setting press simultaneously the the DRYNESS
and START/PAUSE buttons or turn knob to O off position
Hints for test institutes
Parameters possible to checked by the Test
Institutes:
Energy consumption (corrected with final
humidity) during the cupboard dry cotton
cycle with nominal load.
Energy consumption (corrected with final
humidity) during the cupboard dry cotton
cycle with half load.
Final humidity (during cupboard dry cot-
ton, iron dry cotton and cupboard dry easy
care)
Condensation efficiency (corrected with fi-
nal humidity) during cupboard dry cotton
cycle with nominal and half load
All the cycles have to be checked in accord-
ance with EN 61121 (Tumble dryers for
household use – Methods for measuring the
performance).
electrolux 15
Vue de la page 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20

Commentaires sur ces manuels