4.14 Power limitation
Originally the hob is at its highest possible
power level.
To decrease or increase the power
level:
1. Deactivate the hob.
2. Touch for 3 seconds. The display
comes on and goes off.
3. Touch for 3 seconds. or
comes on.
4. Touch . P0 comes on.
5. Touch / of the Timer to set the
power level.
Power levels
Refer to “Technical information” chapter.
• P0 — 7200 W
• P1 — 1500 W
• P2 — 2000 W
• P3 — 2500 W
• P4 — 3000 W
• P5 — 3500 W
• P6 — 4000 W
• P7 — 4500 W
• P8 — 5000 W
• P9 — 6000 W
CAUTION!
Make sure that the selected
power fits to the house
installation fuses.
4.15 Power management
function
• Cooking zones are grouped according
to the location and number of the
phases in the hob. See the illustration.
• Each phase has a maximum electricity
loading of 3700 W.
• The function divides the power
between cooking zones connected to
the same phase.
• The function activates when the total
electricity loading of the cooking zones
connected to a single phase exceeds
3700 W.
• The function decreases the power to
the other cooking zones connected to
the same phase.
• The heat setting display of the reduced
zones changes between two levels.
Power management function with
Power limitation function
When you set the Power limitation function
to 4.5 kW or less, power of the hob is
divided between all cooking zones.
When you set the Power limitation function
to more than 4.5 kW, power of the hob is
divided between two cooking zones in a
pair.
4.16 Hob²Hood
It is an advanced automatic function which
connects the hob to a special hood. Both
the hob and the hood have an infra — red
signal communicator. Speed of the fan is
defined automatically on basis of mode
setting and temperature of the hottest
cookware on the hob. You can also
operate the fan from the hob manually.
For most of the hoods the
remote system is originally
deactivated. Activate it before
you use the function. For
more information refer to
hood user manual.
ENGLISH
11