13.3 Electrical connection
WARNING!
If service is required always
disconnect the appliance
from the power supply.
Use a power cable of H05VV-F or higher.
Install the appliance with a socket supply
line. If there is no socket supply line, the
fixed home electrical system must include
an isolating device with at least a 3 mm-
contact separation to enable a
simultaneous and all-pole cut off from the
mains (according to NIN SEV 1000). The
customer must have a socket for the
electrical connection that is accessible
and outside the coordination room. The
length of the connection cable must be
approximately 120 cm with lines
connected directly to the mains.
Only a qualified person can
connect the appliance to the
electricity supply.
1. Open the mains terminal cover (D).
2. Put the connection cable into the
supplied rings (E).
This is to prevent the cable from
rubbing against the drawer. The
connection cable is on the housing
side.
3. Install the cable grip (F).
4. Connect the terminal as in the
illustration.
5. Put the cable into the strain relief
clamp.
6. Close the mains terminal cover.
7. Do the electrical connections as in the
connection illustration.
Phase definitions: L1, L2, L3 (or R, S,
T).
Voltage: 400V
L2
L3
400V
L1PE L2
400V
L1PE
1 2 3
45
1 2 3
45
400V 2N~
400V
400V
400V 3N~
N N
8. Secure the cable grip.
13.4 Electrical connection with
the hob
You can connect the oven to an
independent hob from the current range of
Electrolux and AEG hobs. You can
ENGLISH