Electrolux EKE5001 Manuel d'utilisateur Page 6

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 48
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 5
6
ELECTRICAL CONNECTIONS
Any electrical work required to install
this hob and the supply cable should be
carried out by a qualified electrician or
competent person, in accordance with the
current regulations.
THIS COOKER MUST BE EARTHED.
The manufacturer declines any liability
should these safety measures not be
observed.
Before any maintenance or cleaning can
be carried out, you must DISCONNECT the
cooker from the electricity supply.
This cooker is designed to be connected to a
230/400V, 50Hz electrical supply.
To connect to the electricity supply, use cable type
H05 RR-F.
Before switching on, make sure the electricity
supply voltage is the same as that indicated on
the rating plate.
The cooker is supplied without supply cord. A
flexible supply cord must be fitted, in
accordance with the specification gived in the
relevant table no. 1.
In case of a direct connection to the mains you
have to interpose an omnipolar switch a
minimum opening between contacts of 3 mm.
The switch should be sited within 2m of the hob
and be easily accessible upon completion of the
installation.
The yellow-green grounding cable has not to be
interrupted by the switch.
NOTE: The earth wire should be about 2 cm
longer than the live and neutral wires.
Ensure that the cooker supply cable does
not come into contact with any part of the
hatched area shown in the diagram.
supply
cable
If the supply cord is damaged, the
manufacturer or its service agent or a
similarly qualified person must replace it in
order to avoid a hazard.
Before connecting check that:
fuse and household electric installation can
bear the charge of the appliance (see rating
plate);
The socket or the omnipolar switch used for
connection is easily reachable when the
appliance is installed.
How to proceed?
Unscrew and remove the protective cover at
the back of the appliance;
Connect the power cord to the terminal of the
cooker according to the table no.1;
Fix by means of cable clamp;
Make sure that the connection to the terminal
is matching the network power;
Remount and screw the protective cover at the
back of the appliance
Table no. 1
Rated voltage 230V 1N, 230/400V 3N, 230V 3~, 230/400V 2N
Connection type Single phase
Tri-phase Y 3 ph.
+ neutral
Tri-phase
Bi-phase Y 2 ph. +
neutral
Cable connection to the
terminal plate
1 2 3
4 5
L1
N
PE
3
L3L1
PE
4 5
N
L2
1 2
L3
5
1 2
3 4
L1 L2
PE
4 5
N
PE
2 3
L2L1
1
Network voltage
1N/ 230 V 3N/400 V 3/230 V 2N/400 V
Voltage of heating
elements
230 V 230 V 230 V 230 V
Fusible capacity
35 A 3 x 16 A 3 x 20 A 2 x 25 A
Cable section
3 x 6 mm
2
5 x 2,5 mm
2
4 x 4 mm
2
4 x 4 mm
2
Vue de la page 5
1 2 3 4 5 6 7 8 9 10 11 ... 47 48

Commentaires sur ces manuels