6 rangehood installation electrolux canopy rangehood
1. Using a spirit level mark a vertical centre line on the wall
where the hood is to be positioned, and a horizontal line
at the hood base position (refer diagram bottom left).
NOTE: The height of the underside of the hood body must
be a minimum of 600mm above an electric cooktop &
650mm above a gas cook top and a maximum height of
800mm (refer to table below).
Distance from hood base to top of hob
hob type minimum* maximum
gas 650mm 800mm
electric 600mm 800mm
* If the instructions of the hob specify a greater distance than the
minimum above, then that shall be the minimum height for installation
2. Markthelocationforuecoverwallmountingbrackets
andrangehoodmountingpointsandanti-tiltxing
points above the hood base using the hood base as the
referencepoint(Fig.A).
3. Installuecoverwallmountingbracketswithsuitable
fixings. Install suitable screws for rangehood mounting
points (to support a total weight of 30kg) to the wall as
marked(Fig.B).
4. Remove the protective plastic film from the hood body
and hang hood on the mounting screws then secure at
theanti-tiltlocationsasindicatedinFig.B.
5. Fixexhausttransitionductusingscrewssupplied(Fig.C).
Rangehood installation
Fig. A
Fig. B
Fig. C
refer table above
“Distancefromhood
base to top of hob”