FITTING POSSIBILITIES
(Dimensions in mm)
On base cabinet with door
Adequate arrangements must be
provided for in the construction of
the cabinet to prevent possible
contact with the overheated
housing of the top during operation.
A possible solution for avoiding this
problem is illustrated in fig. 16.
The panel under the top must be
easily removed to allow securing
and release of the top in case of
technical assistance intervention.
On base cabinet with oven
The compartment must have the
dimensions given in figs. 17 and 20
and must be equipped with
supports for allowing efficient
ventilation.
To avoid excessive overheating, it
is advisable to carry out installation
as shown in Figs. 18 and 19.
The electrical connection of the top
and that of the oven must be
carried out separately, for electrical
reasons and to facilitate frontal
oven removal.
Wall units or extractor hoods must
be at least 650 mm from the
cooktop (Fig. 21).
a) removable cabinet panel
b) possible space useful for
connections
560 min.
Fig. 20
Fig. 21
FO 0198
FO 2099
Fig. 16
Fig. 17
Fig. 18
Fig. 19
FO 1013 FO 2043
FO 0939 FO 0938
120 cm
180 cm
2
360 cm
2
50 cm
2