Connection
Carry out the connection to the gas
plant only by means of a rigid
metallic pipe conforming to the
regulations in force. This appliance
is NOT suitable for connection with
a flexible hose assembly.
The joint for the entry of the gas
into the appliance is threaded
G1/2”.
Carry out the connection avoiding
any type of stress on the appliance
or gas piping.
Natural gas appliances must be
fitted with a pressure regulator
installed at the inlet connection.
The gas pressure is pre-set and the
gas regulator non-adjustable.
For U-LPG the same pressure
regulator may be used by removing
the centre insert and setting it for
U-LPG setting (remove and re-
insert plastic insert inverted).
Alternatively it can be used without
the regulator and set by
adjustments made via the regulator
fitted at the domestic U-LPG
cylinder.