Electrolux EHGC93CI Manuel d'utilisateur Page 11

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 18
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 10
9electrolux gas cooktops gasconnection
Gas connection
This appliance is supplied for use with Natural Gas.
However, it can be converted for use with LPG. Refer
to LP conversion on page 10.
Supply pipe sizing
Thetotalhourlygasconsumptionfortheapplianceis
shownonthedatalabel.Therequiredsupplypressure
(i.e.atinlettoapplianceregulator)foreachgastypeis
shownonthedatalabel,andgiveninTable3(page10).
Usethisinformationinconjunctionwiththelengthofrun,
numberofelbows,teesandbends,theavailableservice
pressureandthesupplyrequirementsofotherinstalled
appliancestodetermineasuitablepipesize.
Forassistanceinthismatterrefertotheappropriate
sectionoftheInstallationCodeAS5601.
AnAGAcertifiedclassBorDflexibleconnectionmay
beusedtoconnectthecooktopinaccordancewith
theAS5601andinparticularsection4.8.Whereahose
assemblyisusedandthecooktopisintheinstalled
position,thehoseassemblyshallbesuitableforconnection
toafixedconsumerpipingoutletlocatedatapoint
800–850mmabovethefloorandintheregionoutside
thewidthoftheappliancetoadistanceof250mm.The
pointofconnectiontoconsumerpipingmustbeaccessible
withapplianceinstalled.
Elbow positioning
Itispossibletorepositiontheelbowifrequiredby
looseningthelockingnutandelbowbyusingtwo
spanners.Re-tightentheentireassemblyaftertheelbow
hasbeenrepositioned.Whenfittingelbowtoappliance,
ensurethatthesealingwasherisfitted.
Regulator
Anapplianceregulatorisprovided.Theregulatormustbe
positionedsothatthepressuretestnippleisaccessible
whentheapplianceisinstalled.
Connectthegassupplytothe½”B.S.P.internalthread
inletoftheregulator.Referto‘benchcutout’(Figure6)for
connectionpointposition.
Regulatorsaresuppliedpre-adjustedandconfiguredbythe
componentmakerforusewithNaturalGas.
Theapplianceinstallerisnotrequiredtomakean
adjustmenttoobtainthecorrectoutletpressuresetting.
Anarrowonthebaseoftheregulatorindicatesthe
directionofgasflowwhentheinletandoutletofthe
regulatorisorientatedcorrectly.Whentheregulatorhas
beenfittedcheckforleaksfromtheconnectionswith
soapywater.
OperationonN.G./S.N.G. OperationonN.G./S.N.G.
Assembly of Regulator
Theassemblyoftheregulatortothecooktopmanifoldis
achievedviatheelbowunionandsealingwashersupplied,
refertofigure9.
The½”parallelthreadconnectstothemanifold,andthe
sealingwasherisplacedbetweenthemanifoldendand
theflatfaceontheelbow.
The½”taperedthreadconnectstotheoutletofthe
regulator,andissealedonthethreadusingapproved
threadsealingtapeorapprovedthreadsealingcompound.
Theinletoftheregulatorisa½”parallelthreadand
isconnectedtoconsumerpipingorhoseassembly.
Regulatorsaresuppliedpre-adjustedandconfigured
bythecomponentmakerforusewithNaturalGas.
Theapplianceinstallerisnotrequiredtomakean
adjustmenttoobtainthecorrectoutletpressuresetting.
Anarrowonthebaseoftheregulatorindicatesthedirection
ofgasflowwhentheinletandoutletoftheregulatoris
orientatedcorrectly.Whentheregulatorhasbeenfitted
checkforleaksfromtheconnectionswithsoapywater.
Figure9
½”Taperedthread
Sealusingapproved
sealingtapeor
approvedthread
sealingcompound
Manifold
endform
Femalenut Flatface
Sealing
washer
½”Parallel
thread
Regulator
Outlet
Inlet
Vue de la page 10