electrolux gas cooktops electricalconnection12
Electricalconnection(220-240Volts)
Appliancesaresuppliedwithastandard7.5Amp
servicecordterminatedbya3-pinplugforconnection
toastandardhouseholdsocket.Theelectricalsupplyis
requiredtopowertheelectronicignitionsystem.
NOTE! It will be necessary for servicing purposes to
disconnect the electrical power supply. The power
point should therefore be accessible after the appliance
is installed, as specified in the local wiring regulations.
Diagram1belowisaschematicofthewiringinthe
appliance.
WEIGHT oftheunitisprintedontheappliance
packaginglabel.
Use of hose assemblies
Ensurethatthehoseassemblyisrestrainedfromaccidental
contactwiththeflueoutletofanunderbenchovenorany
otherhotsurfaceofanadjacentappliance.
Diagram1
DANGER
220-240V VOLTS AC
DISCONNECT FROM SUPPLY
BEFORE REMOVING PANEL
E
E
BODY
2200W
INDUCTION
MODULE
1400W
INDUCTION
MODULE
220-240V
T- ZERO MODULE
220-240V
IGNITION BOX
KNOB IGNITION SWITCH
TO BURNER
THERMOCOUPLE
THERMOCOUPLE
COIL
TO BURNER
SPARK PLUG
BODY
EMC
POWER
FILTER
NL
E
NL
E
E
N
NN L
LN
LSw Sw
L
L
N
L
N
NL 15A
TO BURNER
SPARK PLUG
BODY
220-240V
IGNITION BOX
L
N
KNOB
IGNITION
SWITCHES
TO BURNER
THERMOCOUPLE
THERMOCOUPLE
COILS
NN LLSw Sw
220-240V
T-ZERO MODULE
E
DANGER
220-240V VOLTS AC
DISCONNECT FROM SUPPLY
BEFORE REMOVING PANEL
NLE
BODY
Commentaires sur ces manuels