Do not let the power cable to heat up
to a temperature higher than 90° C.
To prevent contact between the cable
and the appliance below the hob use the
clamps which are on the side of the cabi-
net.
A
A)
Rigid copper pipe or flexible pipe of
stainless steel
8.5 Replacement of the
connection cable
To replace the connection cable use only
H05V2V2-F T90 or equivalent type. Make
sure that the cable section is applicable to
the voltage and the working temperature.
The yellow/green earth wire must be ap-
proximately 2 cm longer than the brown
(or black) phase wire.
8.6 Building In
min.
55 mm
min.
650 mm
560 mm
480 mm
min.
450 mm
30 mm
B
A
A)
supplied seal
B)
supplied brackets
CAUTION!
Install the appliance only on a
worktop with flat surface.
If you install the hob under a
hood, please see the installation
instructions of the hood for the
minimum distance between the
appliances.
8.7 Possibilities for insertion
Kitchen unit with door
The panel installed below the hob must
be easy to remove and let an easy access
in case a technical assistance intervention
is necessary.
min 20 mm
(max 150 mm)
30 mm
60 mm
B
A
A)
Removable panel