14.1 Location of the appliance
You can install your freestanding
appliance with cabinets on one or two
sides and in the corner.
Keep a distance of about 1
cm between the appliance
and the back wall to make
sure that the lid opens.
For minimal distances for fitting check
the table.
Minimum distances
Dimension mm
A 400
B 650
C 150
14.2 Technical data
Voltage 220 - 240 V
Frequency 50 / 60 Hz
Appliance class 1
Dimension mm
Height 850 - 870
Width 600
Depth 600
14.3 Other technical data
Appliance category: II2H3B/P
LPG: G30 (3B/P) 28-30 mbar
Natural Gas: G20 (2H) 20 mbar
14.4 Bypass diameters
BURNER Ø BYPASS 1/100 mm
Auxiliary 29 / 30
Semi-rapid 32
Triple Crown 67
14.5 Gas burners for NATURAL GAS G20 20 mbar
BURNER NORMAL POW‐
ER kW
REDUCED POWER kW INJECTOR MARK
1/100 mm
Triple Crown 4.0 1.80 146
Semi-rapid 2.0 0.45 96
Auxiliary 1.0 0.35 70
ENGLISH 25