12.6 Securing the appliance to
the cabinet
A
B
12.7 Electrical installation
The manufacturer is not
responsible if you do not
follow the safety precautions
from the Safety chapters.
This appliance is supplied only with a
main cable.
12.8 Cable
Cable types applicable for installation or
replacement:
H05 V2V2-F (T90), H05 BB-F
For the section of the cable refer to the
total power on the rating plate and to the
table:
Total power (W) Section of the ca‐
ble (mm²)
maximum 1380 3 x 0.75
maximum 2300 3 x 1
maximum 3680 3 x 1.5
The earth cord (green / yellow cable)
must be 2 cm longer than phase and
neutral cables (blue and brown cables).
13. TECHNICAL INFORMATION
13.1 Technical data
TOTAL POWER: Electric: 1.76 kW
Gas original: G20 (2H) 20 mbar = 2.7 kW
Gas replacement: G30 (3+) 28-30 mbar = 2.7 kW
G31 (3+) 37 mbar = 2.7 kW
Electric supply: 220 - 240 V ~ 50 / 60 Hz
Appliance catego‐
ry:
II2H3+
Gas connection: G 1/2"
Appliance class: 3
13.2 Gas oven burner
Gas type NOMINAL
GAS POW‐
ER (kW)
NOMINAL
GAS
FLOW
(g/h)
Reduced
gas power
(kW)
BY-PASS
NEEDLE
(1/100
mm)
INJECTOR
MARK
(1/100
mm)
G20 (2H) 20 mbar 2.7 - 0.7 Reg.
www.electrolux.com22