12.6 Securing the appliance to
the cabinet
12.7 Electrical installation
The manufacturer is not
responsible if you do not
follow the safety precautions
from the Safety chapters.
This appliance is supplied only with a
main cable.
12.8 Cable
Cable types applicable for installation or
replacement:
H05 V2V2-F (T90), H05 BB-F
For the section of the cable refer to the
total power on the rating plate and to the
table:
Total power (W) Section of the ca‐
ble (mm²)
maximum 1380 3 x 0.75
maximum 2300 3 x 1
maximum 3680 3 x 1.5
The earth cord (green / yellow cable)
must be 2 cm longer than phase and
neutral cables (blue and brown cables).
13. TECHNICAL INFORMATION
13.1 Technical data
TOTAL POWER: Electric: 1.76 kW
Gas original: G20 (2H) 20 mbar = 2.7 kW
Gas replacement: G30 (3+) 28-30 mbar = 2.7 kW
G31 (3+) 37 mbar = 2.7 kW
Electric supply: 220 - 240 V ~ 50 / 60 Hz
Appliance catego‐
ry:
II2H3+
Gas connection: G 1/2"
Appliance class: 3
13.2 Gas oven burner
Gas type NOMINAL
GAS POW‐
ER (kW)
NOMINAL
GAS
FLOW
(g/h)
Reduced
gas power
(kW)
BY-PASS
NEEDLE
(1/100
mm)
INJECTOR
MARK
(1/100
mm)
G20 (2H) 20 mbar 2.7 - 0.7 Reg.
www.electrolux.com22