Electrolux U30280 35772G Manuel d'utilisateur Page 20

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 24
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 19
20
A. EARTH CONTINUITY CHECK
Appliance must be electrically disconnected - meter set on (Ohms) x 1 scale and
adjust zero if necessary.
Test leads from any appliance earth point to earth pin on plug. Resistance should be
less than 0.1 (Ohm), check all earth wires for continuity and all contacts are clean
and tight.
B. INSULATION CHECK
Appliance electrically disconnected, all switches ON.
a) meter set on (Ohms) x 1 scale.
Test leads from L to N in appliance terminal block. If meter reads «0» then there is a
short circuit.
b) meter set on (Ohm) x 100 scale.
Repeat test with leads from L to E. If meter reads less than (infinity) there is a fault.
NOTE - Should it be found that the fuse has failed but no fault is indicated - a detailed continuity
check (i.e. by disconnecting and checking each component) is required to trace the faulty
component.
It is possible that a fault could occur as a result of local burning/arcing but no fault could be found
under test. However a detailed visual inspection should reveal evidence of burning around the
fault.
Vue de la page 19
1 2 ... 15 16 17 18 19 20 21 22 23 24

Commentaires sur ces manuels

Pas de commentaire