The yellow/green earth wire must be ap-
proximately 2 cm longer than the brown
(or black) phase wire.
8.4 Building in
40-50 mm
55 mm
30 mm
min. 650 mm
490 mm
270 mm
If several 30 cm hobs are to be installed
side by side into the same cut out, an as-
sembly kit including a support side brack-
et and supplementary seals is available at
our Service Centres. The relevant installa-
tion instructions are supplied within the kit
package.
=
=
490
+1
mm
270
+1
mm
600mm
R 5mm
8.5 Possibilities for insertion
Kitchen unit with door
The panel installed below the hob must
be easy to remove and let an easy access
in case a technical assistance intervention
is necessary.
min 20 mm
(max 150 mm)
30 mm
60 mm
B
A
A)
Removable panel
B)
Space for connections
Kitchen unit with oven
The hob recess dimensions must obey
the indication and the kitchen unit must
be equipped with vents to let a continu-
ous supply of air. The electrical connec-
tion of the hob and the oven must be in-
stalled separately for safety reasons and
to let easy remove oven from the unit.
50 cm2
360 cm2
180 cm2
120 cm2
ENGLISH 25