• Do not pull the mains cable to
disconnect the appliance. Always pull
the mains plug.
• There is a risk of fire when the
appliance is in connection with an
extension cable, an adapter or a
multiple connection. Make sure that
the ground connection agrees with the
standards and regulations.
• Do not let the power cable to heat up
to a temperature higher than 90° C.
Make sure that you connect
the blue neutral cable to the
terminal with a letter "N" on
it. Connect the brown (or
black) phase cable to the
terminal which has a letter
"L". Keep the phase cable
connected at all times.
8.5 Connection cable
To replace the connection cable use only
the special cable or its equivalent. The
cable type is: H05V2V2-FT90.
Make sure that the cable section is
applicable to the voltage and the working
temperature. The yellow / green earth
wire must be approximately 2 cm longer
than the brown (or black) phase wire.
8.6 Building In
min. 55 mm
min. 650 mm
550 mm
min. 100 mm
30 mm
470 mm
A. supplied seal
B. supplied brackets
CAUTION!
Install the appliance only on
a worktop with flat surface.
8.7 Possibilities for insertion
The panel installed below the hob must
be easy to remove and let an easy
access in case a technical assistance
intervention is necessary.
Kitchen unit with door
min 20 mm
(max 150 mm)
30 mm
60 mm
B
A
A. Removable panel
B. Space for connections
Kitchen unit with oven
The electrical connection of the hob and
the oven must be installed separately for
safety reasons and to let easy remove
oven from the unit.
9. TECHNICAL INFORMATION
9.1 Hob dimensions
Width 580 mm
ENGLISH 13