6
12
10
86
4
2
12
10
86
4
2
Control knob (to the left)
Control knob for regulating the
double plate at the rear
Control knob for regulating the
small plate at the front.
Regulating
The regulating of heat is graduation-free
for both plates on a scale from 1 to 12.
“1” Represents lowest heat
“12” Represents maximum heat.
“0” Represents “OFF”.
Operating the dual plate: When you
switch on the dual plate only the centre
of the cooking zone will operate. Select
the required setting.
To select both cooking zone Turn the
control knob past “12” to stop. Turn
back to the required setting.
To return to centre zone only: Turn the
control knob back to “0”. Control knob
on again and choose the required setting.
Do not use the ceramic hob if the
glass is damaged.
If a fault or crack appears during
cooking disconnect the hob
immediately and contact the
service centre
How to use
Pilot light
15
The electrical connection may only be
performed by a qualified electrician/
competent person. The electrical
connection must be carried out in
accordance with prevailing regulations
for appliances using heavy current.
The connection must comply with any
specific requirements specified by the
local electricity supply authority.
There must be no interference with
any of the unit’s electrical parts.
The cable is mounted in the pegs as
shown.
Unscrew the cover while connecting
the cables.
A unit led directly to the power point
or the outlet rose.
More units may be connected via one
or more junction boxes.
The cable must be connected via an
external switch with a contact
separation of at least 3 mm in each
pole.
Please observe these instructions,
otherwise the warranty will not
cover any damage that may occur.
Single-phase zero-earth
Cable type 1,5 mm² HO5VV-F.
The cable outside diameter must be
between 7,5 and 10,5 mm.