correct oven sockets. The design of the
plugs and sockets prevents incorrect
connections.
10.3 Building In
594
16
573
21548
min. 550
20
600
min. 560
558
589
114
594
3
5
10.4 Securing the appliance to
the cabinet
10.5 Electrical installation
The manufacturer is not
responsible if you do not
follow the safety precautions
from the Safety chapters.
This appliance is supplied without a main
plug and a main cable.
10.6 Cable
Cable types applicable for installation or
replacement:
H07 RN-F, H05 RN-F, H05 RRF, H05
VV-F, H05 V2V2-F (T90), H05 BB-F
For the section of the cable refer to the
total power on the rating plate.
10.7 Connecting the terminal
board
The appliance has a six-pole terminal
board. The jumpers (bridges) are set for
operation on a 400 V three-phase with a
neutral wire.
1 = 45 mm
2 = 45 mm
3 = 60 mm
4 = 60 mm
= 70 mm
1
2
3
4
L 1 – 2 – 3 = phase cables
N 4 = neutral cable
= earth cable
If the mains voltage is different,
rearrange the jumpers on the terminal
board (refer to the connection diagram
below). Connect the ground cable to the
terminal. After you connect the supply
cable to the terminal board, attach it with
a junction clamp.
3N ~
2N ~
230V ~
230V ~
230V ~
230V ~
1 2 3
5 4
1 2 3
5 4
1 2 3
5 4
www.electrolux.com22