Electrolux EQW4111BOZ Manuel d'utilisateur Page 13

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 52
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 12
A
B
5. If you change:
from natural gas G20 20 mbar to
liquid gas, fully tighten the bypass
screw in.
from liquid gas to natural gas G20
20 mbar, undo the bypass screw
approximately 1/4 of a turn.
WARNING!
Make sure the flame does not
go out when you quickly turn
the knob from the maximum
position to the minimum
position.
8.5 Electrical connection
Make sure that the rated voltage and
type of power on the rating plate agree
with the voltage and the power of the
local power supply.
This appliance is supplied with a mains
cable and a plug.
Always use a correctly installed
shockproof socket.
Make sure that there is an access to
the mains plug after the installation.
Do not pull the mains cable to
disconnect the appliance. Always pull
the mains plug.
There is a risk of fire when the
appliance is in connection with an
extension cable, an adapter or a
multiple connection. Make sure that the
ground connection agrees with the
standards and regulations.
Do not let the power cable to heat up
to a temperature higher than 90° C.
Make sure that you connect
the blue neutral cable to the
terminal with a letter "N" on it.
Connect the brown (or black)
phase cable to the terminal
which has a letter "L". Keep
the phase cable connected at
all times.
8.6 Connection cable
To replace the connection cable use only
the special cable or its equivalent. The
cable type is: H05V2V2-FT90.
Make sure that the cable section is
applicable to the voltage and the working
temperature. The yellow / green earth wire
must be approximately 2 cm longer than
the brown (or black) phase wire.
8.7 Assembly
ON-TOP INSTALLATION
min.
450mm
min.
650mm
ENGLISH
13
Vue de la page 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 51 52

Commentaires sur ces manuels

Pas de commentaire