Natural Gas: G20 (2H) 20 mbar
14.4 Bypass diameters
BURNER Ø BYPASS 1/100 mm
Auxiliary 29 / 30
Semi-rapid 32
Rapid 42
Triple Crown 67
Oven 54
Grill 59
14.5 Gas burners for NATURAL GAS G20 20 mbar
BURNER NORMAL POW‐
ER kW
REDUCED POWER kW INJECTOR MARK
1/100 mm
Triple Crown 4.0 1.8 146
Rapid 3.0 0.72 119
Semi-rapid 2.0 0.43 96
Auxiliary 1.0 0.35 70
Oven 3.9 1.5 136
Grill 3.0 1.6 126
14.6 Gas burners for LPG G30 28-30 mbar
BURNER NORMAL POW‐
ER kW
REDUCED POWER kW INJECTOR MARK
1/100 mm
Triple Crown 4.0 1.8 101
Rapid 3.0 0.72 88
Semi-rapid 2.0 0.43 71
Auxiliary 1.0 0.35 50
Oven 3.9 1.5 95
Grill 3.0 1.6 88
14.7 Gas connection
The gas pipe in the appliance has two
endings. You can connect the gas supply
to either one of them. The pipe that is not
used must be clogged with the pipe
closer, which added to the appliance.
Use a fixed connections or use a flexible
stainless steel pipes in compliance with
the regulation in force. If you use flexible
ENGLISH 25