electrolux 25
Gas connection must be carried out
according to the rules in force. The manufac-
turing company release the unit, once tested,
adjusted for the kind of gas stated on the
rating plate located on the back of the range,
next to connection pipe. Be sure that you are
going to connect the unit to the same kind
of gas written on the plate.
Gas connection (Fig. 14)
LPG : use the pipe holder «A».
Natural gas : use the pipe holder «B».
Always insert the gasket «C». Then
proceed with the gas connection, as indi-
cated in the relevant paragraphs.
Connection
using a rigid pipe or a flexible
metal pipe
To ensure higher safety, it is recom-
mended to carry out the connection to the
gas system using rigid pipes (ex. copper) or
using flexible stainless steel pipes, to avoid
any stress to the unit. Gas feeding pipe fitting
is Gc 1/2. For this type of installation,
connection to the gas supply should be
carried out using only and exclusively flexible
metallic tubes in conformity with rules in
force.
Connection
using flexible non metal
pipes
When the connection can be easily
inspected in its full extent, there is the chance
to use a flexible pipe according to the rules
in force. The flexible pipe must be tightly fixed
using clamps according to the rules in force.
Gas connection
Fig. 14