ENGLISH 14
6.4. Anti-cold air function
In HEAT mode, the indoor fan will not
operate in order to prevent cold air from
blowing out if the indoor heat exchanger
does not reach a certain temperature in
one of the following situations:
when the heating operation starts;
when the defrosting operation is
finished;
when heating at low temperature.
6.5. Gentle breeze
The indoor unit may blow gentle breeze
and the horizontal louvre rotates to
acertain position in one of the following
situations:
In HEAT mode, the compressor does
not start operation after switching on
the unit.
In HEAT mode, the temperature
reaches the set value and the
compressor has stopped operation for
1 minute.
6.6. Opetaring temperature
range
The operating temperature range for
cooling-only units is 0-50 ˚C. The
operating temperature range for heat-
pump units is -15-(+30)˚C.
Indoor side (°C) Outdoor side (°C)
Max. cooling 32 50
Min. cooling 17 0
Max. heating 30 30
Min. heating 0 -15
6.7. Tip for energy saving
Do not overcool or overheat. Setting
the temperature at a moderate level
helps energy saving.
Cover windows with a blind or a
curtain. Blocking sunlight and air from
outdoor is favorable for cooling.
Clean air filters every two weeks.
Clogged air filters lead to inefficient
operation and energy waste.
6.8. Tip for relative humidity
If the unit is operated in an area with
a relative humidity of more than 80%
for a long time, condensate may drip
from the indoor unit.
7. INSTALLATION
7.1. Installation notes
Not following the instructions can
cause personal injury and/or property
damage.
Not following the instructions can
cause the unit to fail.
Let the unit be installed by an
authorised service centre.
Let the unit be installed in compliance
with local and governmental
regulations.
Let the unit be installed according to
the instructions from this manual.
First contact an authorised service
centre before relocating an already
installed unit
Disconnect power before working on
the unit.
The mains plug must remain
accessible after installation.
Keep sufficient distance between the
interconnection cable and the
refrigerant circuit because the circuit
operating temperature is high.
The pipes connecting the indoor and
outdoor unit are not included in the
unit.