ENGLISH 18
7.4. Indoor unit
Installing the mounting plate
Fit the installation plate horizontally
on structural parts of the wall with
spaces around the installation plate.
If the wall is made of brick, concrete
or the like, drill five or eight 5mm
diameter holes in the wall. Insert Clip
anchor for appropriate mounting
screws.
Fit the installation plate on the wall
with five or eightSelf-tapping Screw
ST3.9x25.
NOTE:
Mount the Installation Plate and drill
holes in the wall according to the wall
structure and corresponding mounting
points on the installation plate.
The installation plate provided
with the machine differ from appliance
to appliance.
Dimensions are in mm unless
otherwise stated.
150mm or more to ceiling
120mm or
more to wall
120mm or
more to wall
Indoor unit outline
18000Btu/h models
Left rear side
refrigerant pipe
hole Ø 65
Right rear side
refrigerant pipe
hole Ø 65
12000Btu/h models
120mm or
more to wall
120mm or
more to wall
Left rear side
refrigerant pipe
hole Ø 65
Right rear side
refrigerant pipe
hole Ø 65
150mm or more to ceilin
g
Indoor unit outline
150mm or more to ceiling
120mm or
more to wall
Left rear side
refrigerant pipe
hole Ø 65
9000Btu/h models
120mm or
more to wall
Indoor unit outline
Right rear side
refrigerant pipe
hole Ø 65